Reaching upwards
Height of the hazard zone above the reference plane, where nothing restricts the reach. The reference plane is where people normally stand, which may be a platform rather than the floor.
Reaching over a protective structure
Find the horizontal distance sh from the barrier to the hazard, given the hazard height hh and the barrier height hps. Use Table 2 unless both injury severity and probability are low. Values are never interpolated: the lookup takes the safer of the bracketing rows and the next lower barrier height.
Reaching through openings
The opening size e is the side of a square, the diameter of a round hole, or the narrowest width of a slot. Measure the safety distance sr from the surface of the opening to the hazard.
Find the smallest round hole, the smallest square and the narrowest slot that the irregular opening fits completely inside. Look up each one in Table 4 or 5. You may use the shortest of the three distances.
Reaching around
For openings up to 120 mm (persons 14 and over), supporting the arm on a surface limits how far it can bend towards the hazard. Distances below 850 mm need the supporting surface to be at least 300 mm long. Surfaces the arm rests on may be inclined at any angle.
| Table 3 · Limitation of movement | Support length | sr |
|---|---|---|
| Only at shoulder and armpit | — | ≥850 |
| Arm supported up to elbow | ≥300 | ≥550 |
| Arm supported up to wrist | ≥620 | ≥230 |
| Arm and hand supported to knuckle joint | ≥720 | ≥130 |
| Table 6 · Additional protective structures | Safety distances |
|---|---|
| Movement limited at shoulder and armpit, with two separate structures: one allows movement from the wrist, the other from the elbow | sr1 ≥230 · sr2 ≥550 · sr3 ≥850 |
| Movement limited at shoulder and armpit, with one separate structure that allows movement from the fingers to the knuckle joint | sr3 ≥850 · sr4 ≥130 |
Lower limbs through openings
Use Table 7 on its own only where the risk assessment shows the upper limbs cannot reach the opening. Otherwise use the upper-limb tables. Values apply to persons 14 and over, with or without footwear.
- a · Slot 15 < e ≤ 35 mm: if the slot length is 75 mm or less, the distance may be reduced to ≥50 mm.
- b · Value corresponds to the leg from toe tip to knee.
- c · Value corresponds to the leg from toe tip to crotch.
- Slots wider than 180 mm and squares or round openings over 240 mm allow whole body access.
Impeding free access by the lower limbs
Where the safety distances cannot be applied, for example on mobile agricultural machines, an extra structure can restrict leg movement under an existing structure. These are not safety distances, and other measures may still be needed. The gap h from the reference plane should not exceed 180 mm. Do not interpolate: use the row for the higher value of h.
| Height h to structure | Case 1, l | Case 2, l | Case 3, l |
|---|---|---|---|
| h ≤ 200 | ≥340 | ≥665 | ≥290 |
| 200 < h ≤ 400 | ≥550 | ≥765 | ≥615 |
| 400 < h ≤ 600 | ≥850 | ≥950 | ≥800 |
| 600 < h ≤ 800 | ≥950 | ≥950 | ≥900 |
| 800 < h ≤ 1 000 | ≥1 125 | ≥1 195 | ≥1 015 |
Cases 1 to 3 are the standing positions shown in Figure B.1 of the standard. These values may not be suitable where there is a risk of slipping or misuse.
Whole body access
Always consider climbing over and crawling under protective structures. The distances assume no ladders, chairs, tools or jumping, and that guards keep their shape and position.